About The Kit
Immunoglobulin E Detection
Lateral Flow Immunochromatographics Assay
A rapid diagnostic test designed to detect total Immunoglobulin E (IgE) levels in the body. It aids in the identification of allergic conditions such as asthma, food allergies, and skin reactions. Suitable for quick screening in clinics, laboratories, and point-of-care (POC) settings.
Our Values That Drive Success
Gives Fast Results
Receive your test results within minutes, helping you make timely and informed decisions.
High Accuracy
Engineered with advanced diagnostic technology to provide dependable and consistent performance.
User-Friendly Design
Simple testing procedure with easy-to-read control and test lines.
Hygienic & Safe
Each test is individually packed to ensure product integrity and user safety.
Technical Specifications
| Parameters | Specifications |
|---|---|
| Test Technology | Lateral Flow Immunochromatographic Assay (LFIA) |
| Limit of Detection | 20 IU |
| Result Type | Qualitative (positive, negative, or semi-quantitative) |
| Ease of Use | Simple; no specialized training required. |
| Accuracy | High sensitivity and specificity (as per validation) |
| Sensitivity | 100% |
| Specificity | 99% |
| Regulatory Scope | ISO 13485 |
Key Features
No laboratory equipment required. Ideal for clinics, small labs and field use settings.
Results in 15 minutes, enabling immediate clinical decision-making at point of care.
24-month shelf life. Stored at 2–30°C. Cassette format available.
10 µL for plasma/serum and 20 µL for whole blood. Suitable for whole blood, serum, or plasma samples.
Test Procedure
Collect a whole blood, serum, or plasma sample.
Step 1➤
Add ~10 µL serum/plasma, or ~20 µL whole blood to the sample well 'S'.
Step 2➤
Add 2 drops (~80 µL) of buffer to sample well 'S'.
Step 3➤
Read the result after 15 minutes.
Step 4Result Interpretations
Negative
Positive
Positive
Invalid
Invalid
| IgE Calibrator Concentration | Colour Intensity |
|---|---|
| Assay Buffer Only | AB |
| 100-120 IU/mL | T1 |
| 200 IU/mL | T2 |
| 300 IU/mL | T3 |
| 400 IU/mL | T4 |
| 500 IU/mL | T5 |
| 600 IU/mL | T6 |
| >700 IU/mL | T7 |
Place Your Test Device here
Ordering Information
| Catalogue No | Pack Size | OEM | White Label | Watchline |
|---|---|---|---|---|
| 10799 | 10 Tests | ✓ | ✓ | ✓ |
| 10800 | 25 Tests | ✓ | ✓ | ✓ |
| 10801 | 50 Tests | ✓ | ✓ | ✓ |
| 10802 | 100 Tests | ✓ | ✓ | ✓ |
Quality Statement
Excellence Through Quality
At Prahas Healthcare, we strive for excellence by combining advanced technology, stringent quality management, and continuous innovation. Every diagnostic product is carefully manufactured and thoroughly inspected to ensure superior reliability, safety, and performance. Our unwavering commitment to quality enables us to deliver trusted healthcare solutions that meet the expectations of medical professionals and patients alike.
